No products in the cart.
Mouse over to zoom in
Product Highlights
Designed to generate the surge test described in Clause 68.302(d) Power Line Surge. Output voltage is 2500 volts minimum, peak short circuit current is 1000 amperes minimum. A switch is provided for reversal of output polarity. Optional divider network available for oscilloscope connection. This MegaPulse tester has isolated outputs; that is, no ground reference.
The waveform generated is 2×10/2×10, Vp=2500V. To test, the front panel meter is set to 2500V.
A coupling/decoupling network is required to provide isolation between the DUT, the MegaPulse Power Line and the mains power when the pulse is applied. We can supply our CDN 240/15, built to the requirements of EN61000-4-5 and for use on single phase circuits up to 240Vac and up to 15 amps.
- Generates the waveforms required by TIA/EIA-IS-968 (formerly known as FCC Part 68), Paragraph 68.302, for testing of Unpackaged Registered Terminal Equipment and Registered Protective Circuitry.
- Designed with operator safety in mind: Set up the EUT to the right and behind the tester, and a right-handed operator will find himself standing to the left of the tester, allowing maximum separation.
- Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse within the 968 Series, allowing checks and proof of test setups.
- 1000:1 BNC Oscilloscope output option allows quick connections and easy evaluation of output waveforms.
- Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors.
- Front panel voltage meter shows residual voltage in charging circuit for safer operation.
- 1-year calibration cycle.
- All test leads included.
- 1 year warranty.
Reviews
There are no reviews yet.